Crankcase blow-by gas is produced when combustion gasesunder high pressure escape past piston rings into the crankcase. As theseblow-by gases pass though the crankcase, they become contaminated with oilmist. In enclosed areas, like generator sets or engine rooms, the contaminatedgas coats and damages surrounding equipment, resulting in hazardous conditionsand the need for costly maintenance. Uncontrolled blow-by oil mist also coatsengine after-coolers and turbochargers, which reduces cooling capacity andengine efficiency.
Racors Crankcase Ventilation Systems prevent this problem by removing mist andcontamination in blow-by gases. In closed systems (CCV), the high efficiencyfilter prevents fouling of the turbocharger and after-cooler. In open systems(CV), it prevents fouling of surrounding equipment and walls, thus allowingclean exhaust to vent directly to the atmosphere.
The systems have stainless steel latches for tool-less element change and ametal housing (steel for the 4500 unit and aluminum for 6000, 8000 & 12000units) with an epoxy powder coating. They also have a drain check valve, whichallows collected oil to return to the crankcase, resulting in drasticallyreduced oil consumption.
Open systems are acceptable for certain engines and situations. However, inrecent years, environmental concerns and legislation to control crankcaseemissions have increased significantly. New laws to further reduce the totalemissions of engines often make it necessary to close the crankcase breathersystem. In this case, blow-by gases are routed into the inlet of theturbocharger where they can be burned instead of polluting the environment.
How they work:
CCV Series (Closed Crankcase Ventilation Systems) - Racors CCV (closed) systemsalso utilize depth-loading, micro-glass fiber Vaporbloc™ media. In thesesystems, blow-by gasses are not allowed to vent to the atmosphere. Instead, thecleaned and filtered gases are routed back to the inlet of the turbocharger tobe burned in the engine. The units are designed to handle crankcase flow ratesup to 50 cfm (1.42 m3/m) or more when using multiple units. CCV units feature aunique crankcase pressure regulator with an integral bypass valve. Thisregulator protects against crankcase over-pressure and under-pressure, thuspreventing damage to seals and oil loss.
Use in Marine Applications - Marine diesel engines can benefit from theinstallation of a combination CCV and air filter/silencer system. The CCVcontains Racors high-performance Vaporbloc™ filter media. Marine airfilter/silencers (AF Series) contain washable media and are ruggedly built toprovide extended service life.
When installed, the engine crankcase breather is connected to the inlet of theRacor CCV Assembly. The CCV outlet is connected to the engines combustion airinlet via an air intake connector where filtered blow-by gas is recycledthrough the combustion process. Oil collected in the CCV sump is returned tothe crankcase through a hose and a drain check valve.
Benefits:
• Prevents fouling of critical engine components, such as turbochargers andafter-coolers by removing oil contamination from engine bypass gases.
• Reduces operating costs and improves safety in enclosed areas, wherecontaminated gas from engines can coat and damage surrounding equipment,resulting in hazardous conditions and the need for costly maintenance.
• Minimal maintenance requirements. Typical service life of thehigh-performance crankcase ventilation system in diesel applications is 750hours.
• Drain check valve allows collected oil to return to the crankcase, resultingin drastically reduced oil consumption.
• Available in open (CV) or closed (CCV) configurations to meet the uniquerequirements of customers’ engines.
• Suitable for use in marine applications. ‘
Features:
• Racor crankcase ventilation units for closed or open systems
• High efficiency oil separation down to 0.3 micron
• Unique crankcase pressure regulator
• Replaceable high-performance filter
• Depth loading, micro-glass fiber coalescing Vaporbloc™ media
• Steel housing with epoxy powder coating
• Drain check valve
• Left or right inlet ports
• Closed units offer bypass or non-bypass options
• Closed units offer pop-up style, or remote indicator of bypass condition
• Compatible with flow rates up to 50 cfm (1.42 m3/m)
• Continuous operating temperature range -40? to 240?F (-40?C to 116?C)
Optional Kits:
• CCV Fitting/Hose Kits
• CCV 90? Hose Adapters
• CCV hose Barbs
• Bulk Hose Kits
• Hump Hose Fittings
• CCV8000 Conversion Kits (covert to CCV12000)
• CCV Heater Kits
• Electronic Remote Filter Gauge
• Heavy-Duty Wear Spacers
• Tap Sleeves
Height: 12.03” (30.56 cm)
Width: 8.59” (21.82 cm)
Depth: 7.3” (18.54 cm)
Weight: 5.0 lbs (2.3 kg)
Ports: 1 5/8-12 UN-2B
SAE O-ring Thread
Service Clearance (Bottom):
4.0” (10.2 cm)
Max Airflow: 20 CFM (566 LM)
Max Engine Rating: 800 HP (597 KW)
Note: Closed system CCV assemblies
include a visual bypass indicator.
Hose Fittings sold separately
Weight | 8.4 lbs (3.8095 Kg) |
---|---|
Barcode | 706672013385 |
Image | Part No | Descriptions | Notes |
---|---|---|---|
CCV55046 | Racor Engine Crankcase Breather Hose Kit. 1.5 Inch to 1.25 Inch | Hose or Fitting Kit - 2 1.25 Inch fittings, 1 1.25 Inch ID x 8 foot hose, 4 clamps, 4 ties | |
CCV55047 | Racor Engine Crankcase Breather Hose Kit for CCV600 Series 1.25 to 1.25 Inch Crossover | Hose or Fitting Kit - 2 1.25 Inch fittings, 1 1.25 Inch Tee fitting, 1 1.25 Inch ID x 10 foot hose, 8 clamps, 8 ties | |
![]() | CCV55048 | Racor Engine Crankcase Breather Hose | Hose or Fitting Kit - 2 1.25 Inch fittings, 1 1.5 Inch ID x 4 foot hose, 1 bushing reducer, 1 1.25 Inch ID x 4 foot hose, 4 clamps, 4 ties |
CCV55049 | Racor Engine Crankcase Breather Hose | Hose or Fitting Kit - 2 1.25 Inch fittings, 1 1.5 Inch ID x 5 foot hose with 2 Inch cuff, 1 bushing reducer, 1 1.25 Inch ID x 4 foot hose, 4 clamps, 4 ties | |
CCV55081 | Racor CCV4500, CCV4501, CCV6000, CCV6001, CCV8000, CCV8001, CCV12000, CCV12001 Bypass Filter Change Indicator Kit | ||
![]() | CCV55089 | Racor Engine Crankcase Vent Filter Fitting | Inlet or Outlet Fitting - .75 Inch OD Hose Bard to 1.625 Inch SAE |
![]() | CCV55121 | Racor Engine Crankcase Breather Pipe | Inlet or Outlet Fitting 90 Degree - 1.25 Inch OD Hose Barb to 1.625 Inch SAE |
![]() | CCV55267 | Racor Fuel Filter Fitting | Inlet or Outlet Fitting - 1.5 Inch OD Hose Barb to 1.625 Inch SAE |
CCV55268 | Racor Engine Crankcase Breather Pipe | Inlet or Outlet Fitting - 1.25 Inch OD Hose Barb to 1.625 Inch SAE | |
![]() | CCV55273 | Racor CCV6000/CCV6001 Diaphram Kit - Includes Diaphram Springs Top and Bottom, Housing Gasket and O Ring | |
CCV55274-08 | Racor Crankcase Ventilation System Filter, Fits CCV6000 Series used on Caterpillar 163-7344 and John Deere Engines | ||
CCV55274-10 | Racor CCV6000/CCV6001 Replacement Element - Ultra Density - Includes Housing Gasket and O Ring | ||
![]() | CCV55275 | Racor Engine Crankcase Body Assembly | |
![]() | CCV55385 | Racor Filter Element | Heavy-Duty Wear Spacer - Protects element from excesive vibrations |
![]() | CCV55462 | Racor Engine Air Intake Heater | CCV Heater Kit - 120v AC 150w |
![]() | CCV55462-24 | Racor Engine Air Intake Heater | CCV Heater Kit - 24v DC 150w |
![]() | CCV55272L | Racor CCV6000 Head Assembly (Bypass Assy.) - (L) Left Inlet - Includes CCV55081 CCV55273 Diaphram Kit, Housing Gasket and Head Assembly Bracket | |
![]() | CCV55022 | Racor Drain Kit - 3/8” I.D. x 3’ Hose, Check Valve, (2) Swivel Fitting | |
![]() | CCV55615-01 | Racor Dash Indicator Light | Electronic Remote Filter Gauge Kit |
![]() | CCV55462-12 | Racor Engine Air Intake Heater | CCV Heater Kit - 12v DC 150w |
![]() | CV1034-01-C | Racor Engine Crankcase Breather Hose | Inlet or Outlet Hose - .75 Inch ID Hose Per Ft. |
![]() | CV1112-01-C | Racor Engine Crankcase Breather Hose | Inlet or Outlet Hose - 1.5 ID Hose Per Ft. |
![]() | CV1114-01-C | Racor Engine Crankcase Breather Hose | Inlet or Outlet Hose - 1.25 ID Hose Per Ft. |
Competitor Part Number | Competitor Name | Interchange Type | Notes |
---|---|---|---|
CCV6000-08L | RACOR | Direct Replacement | |